18مم وحدة واحدة RCBO, 6كا, 1P + N 10mA, قاطع دائرة قادر على التغذية المزدوجة - ZHISHUN ELECTRICAL

RCBO/

18مم وحدة واحدة RCBO, 6كا, 1P + N 10mA, قاطع دائرة قادر على التغذية المزدوجة

OSR2-40 RCBO - Smart Circuit Protection by ZHISHUN

Premium Safety Features

  • Dual Protection: Combines RCD (earth leakage) + MCB (overload/short-circuit)
  • Wide Current Range: 6A-40A (6,10,16,20,25,32,40A)
  • Type A/AC Detection: Catches AC + pulsating DC faults (ideal for EV chargers)
  • 30mA/100mA/300mA Sensitivity: Personal shock & fire protection
  • 6kA Breaking Capacity: Reliable fault interruption

Technical Highlights

  • Standards: IEC61009-1, CE, CB certified
  • Voltage: 230/240V AC
  • Tripping Curves: B (3-5x In) / C (5-10x In)
  • Operating Temp: -25°C to +40°C
  • Compact 1P Design: Space-saving installation
  • Bottom Wiring: Easy connection

Why Choose OSR2-40?
All-in-one safety - No need for separate RCD+MCB
EV charger ready - Type A detects DC leakage
Global certifications - Meets international standards

Best for: Homes • EV Stations • Solar Systems • Commercial Buildings

  • تفاصيل المنتج
  • Why Choose OSR2-40 RCBO
  • Packing & Delivery
  • الأسئلة الشائعة

Porduct Overview

OSR2-40 1P+N RCBOAdvanced Circuit Protection Solution

Core Protection Features:

  • Single-module design combining RCD + MCB protection
  • Comprehensive coverage against:
    • Short-circuit currents
    • Overload conditions
    • Earth fault currents (10/30/100/300mA sensitivity)
    • Indirect/direct contact hazards
  • Built-in supply neutral wire for enhanced safety

Technical Advantages:

  1. Superior Fault ProtectionNeutral wire ensures reliable earth fault and overcurrent detection
  2. Critical Environment ReadyIdeal for medical facilities and sensitive electronic installations
  3. Regulation CompliantMeets strict industry requirements for functional earth wiring
  4. Installation EfficiencySimplified wiring saves valuable installation time
  5. Space-Saving DesignCompact 1P+N configuration optimizes panel space

Optimal Applications:

  • Healthcare facilities and medical equipment
  • Laboratory and research environments
  • Data centers and server rooms
  • Industrial control systems
  • Sensitive electronic installations

Key Benefits:
✔ Dual-function protection in one device
✔ Neutral wire enhances system reliability
✔ Meets stringent safety regulations
✔ Quick and easy installation process
✔ Compact footprint saves space

OSR2-40 RCBO Technical Specifications

Category Parameter Specification
Certification معيار IEC/EN61009-1
Protection Types Ground Fault Electronic trip
Overcurrent/Short Circuit Thermo-magnetic trip
Over-voltage Selectable
كهربائي Leakage Protection Type AC, A
اعمده 1P + N (1 module)
Neutral Line Disconnected
Rated Current (In) 6,10,16,20,25,32,40A
Sensitivity (IΔn) 10,30,100,300ما
Trip Time (IΔn) ≤0.1s
Rated Voltage (Ue) 230/240V~
Frequency 50/60هرتز
Breaking Capacity 6,000A
Impulse Withstand Voltage 4,000V (1.2/50μs)
Dielectric Test Voltage 2كيلوفولت (1 min)
Tripping Thermal Release (1.13-1.45) x In
Magnetic Release B:3-5x In, C:5-10x In
الميكانيكيه Electrical Life 4,000 cycles
Mechanical Life 10,000 cycles
Contact Indicator نعم
Protection Degree IP20
Environmental Operating Temperature -25℃ to +40℃
Humidity Max 95%
تركيب Terminal Type Cable/Pin-type busbar
Max Cable Size L(in):25mm², N/L(out):16mm²
Tightening Torque L(in):2.5N·m, N/L(out):2N·m
تصاعد 35mm DIN rail
اتصال Bottom only

Key Features of This Table:

ابعاد

1. All-in-One Protection

  • Combines التجمع (earth leakage) + MCB (overcurrent/short-circuit) protection in a single compact module
  • Covers: ماس كهربائي, الزائده, earth faults, and direct/indirect contact risks

2. Enhanced Safety with Neutral Wire

  • Built-in neutral disconnection ensures reliable protection against earth faults and overcurrents
  • Critical for medical facilities, labs, and sensitive electronics where safety is paramount

3. Flexible Sensitivity Options

  • 10mA/30mA/100mA/300mA versions available:
    • 30ما: Personal shock protection
    • 100mA/300mA: Fire prevention

4. Compliant & Reliable

  • Meets IEC/EN61009-1 standards
  • Certified for use in regulated environments (healthcare, industrial, etc.)

5. Easy Installation

  • 1P+N design saves space in distribution boards
  • Bottom wiring for faster, cleaner installations

Best For:

  • Hospitals & Medical Equipment – Ensures uninterrupted power for critical devices
  • Data Centers – Protects servers from electrical faults
  • Industrial Controls – Handles motor inrush currents (C-curve)
  • Labs & Precision Electronics – Prevents leakage-induced interference

Key Benefits:

Space-saving – No need for separate RCD+MCB
Safety-first – Neutral wire adds extra protection layer
Versatile – Multiple sensitivity options for different needs
Quick setup – Simplified wiring reduces installation time

 

اختيار الشحن

Q1: Wonder if you accept small orders?

A1: Do not worry. Feel free to contact us .in order to get more orders and give our clients more convenient ,we accept small order.

Q2: Can you send products to my country?

A2: Sure, we can. If you do not have your own ship forwarder, we can help you.

Q3: Can you do OEM for me?

A3: We accept all OEM orders,just contact us and give me your design.we will offer you a reasonable price and make samples for you ASAP.

Q4: What’s your payment terms ?

A4: By T/T,LC AT SIGHT,30% deposit in advance, balance 70% against the copy of B/L.

Q5: How can I place the order?

A5: First sign the PI,pay deposit,then we will arrange the production.After the goods finished production we will send u the copy of B/L then u paid. Finally u will get the goods.

Q7: When can I get the quotation ?

A7: We usually quote you within 24 hours after we get your inquiry. If you are very urgent to get the quotation.Please call us or tell us in your mail, so that we could regard your inquiry priority.