Introduction:
OSR5-40 RCBO – Ultra-Slim 18mm 1P+N Protection (6-40A, 6kA, Type A/AC)
Complete Safety in 1 Module:
✔ Dual Protection – Combines RCD (30/100maman) + MCB functions
✔ Type A Detection – Catches AC + pulsating DC (EV/solar ready)
✔ 6kA Breaking Capacity – Reliable fault protection
✔ Energy Limiting Class 3 – Highest fire prevention rating
Key Advantages:
- 18mm width (1-module) saves panel space
- Non line/load sensitive – Top/bottom wiring options
- Full L+N disconnection – Works even if wiring reversed
- B/C tripping curves available
- IEC/EN 61009-1 certified
Critical Applications:
- EV charging points
- Solar installations
- Caravan parks & marinas
- Hospitals & schools
- High-rise residential
Why Installers Choose OSR5-40:
✓ Prevents nuisance tripping in sensitive locations
✓ Simplifies upgrades (replaces RCCB+MCB combos)
✓ Easy DIN rail installation
✓ 6A-40A current range (6,10,16,20,25,32,40A)
Keywords:
18mm slim RCBO, Type A circuit breaker, 1P+N 6kA protection, EV charger safety switch, energy limiting class 3
Product Description:

OSR5-40 RCBO – Ultra-Slim 1P+N Protection (2-40A, 6kA, Type A/AC)
Complete Safety in 18mm Width:
✔ Dual Protection – RCD (30/100maman) + MCB in single module
✔ Type A Detection – Catches AC + pulsating DC (EV/solar ready)
✔ 6kA Breaking – Reliable fault interruption
✔ B/C Curves – B(3-5x) homes, C(5-10x) commercial
Key Technical Specs:
- Currents: 2A-40A (2,6,10,16,20,25,32,40A)
- Voltage: 110V/230V AC
- Impulse Withstand: 6kV
- Mechanical Life: 20,000 ops
- IP20 protection
Installation Advantages:
- True L+N Disconnect – Full isolation
- Top/Bottom Wiring – Flexible connections
- Neutral Switching – Faster testing
- 35mm DIN Rail – Standard mounting
Certified: IEC/EN 61009-1
Best For:
- Space-limited panels
- EV chargers (Type A)
- Solar systems
- Caravan parks
Category | Parameter | Specification |
---|---|---|
Standard Certification | Compliance Standards | IEC 61009-1, EN 61009-1 |
Electrical Features | Rated Current (In) | 6,10,16,20,25,32,40A |
Device Type | Electronic | |
Leakage Detection Type | Type A or AC | |
Poles | 1P+N | |
Rated Voltage (Ue) | 230/240V | |
Sensitivity (IΔn) | 30maman,100maman,300maman | |
Insulation Voltage (Ui) | 500V | |
Frequency | 50/60Hz | |
Breaking Capacity | 6kA | |
Impulse Withstand Voltage (1.2/50μs) | 6kV | |
Pollution Degree | 2 | |
Tripping Characteristic | B, C Curve | |
Mechanical Features | Electrical Life | 2,000 operations |
Mechanical Life | 20,000 operations | |
Contact Indicator | Yes | |
Protection Degree | IP20 | |
Reference Temperature | 30°C | |
Environmental Ratings | Operating Temperature | -5°C to +40°C |
Storage Temperature | -25°C to +70°C | |
Installation | Terminal Type | Cable/Pin-type busbar |
Cable Size (Top/Bottom) | 16mm² / 18-5 AWG | |
Busbar Size (Top/Bottom) | 10mm² / 18-8 AWG | |
Tightening Torque | 2.5N·m / 22 In-lbs | |
Mounting | 35mm DIN Rail (EN 60715) | |
Connection | From top or bottom |