The AHR3-63 is a premium Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to deliver comprehensive electrical safety for residential, commercial, and industrial applications. Its innovative dual-protection design combines earth leakage detection with overload/short-circuit protection in a single compact unit.

Key Features & Benefits:

Dual Protection Technology

  • 30mA/100mA/300mA residual current protection (RCD)
  • Overload and short-circuit protection (MCB)
  • Electromagnetic tripping mechanism for reliable operation

EV Charger Ready

  • Type A version detects pulsating DC currents (essential for EV charging stations)
  • True double-pole disconnection (L+N) meets EV installation requirements

Superior Performance

  • 10kA breaking capacity
  • B and C tripping curves available
  • Rated current: 6A-63A (multiple options)

Installation Advantages

  • Neutral pole switching reduces commissioning time
  • Double handle design for independent control
  • 35mm DIN rail mounting
  • Top/bottom wiring options

Technical Specifications:

  • Standards: IEC 61009-1, EN 61009-1
  • Rated Voltage: 230/240V AC
  • Insulation Voltage: 500V
  • Mechanical Life: 10,000 operations
  • Protection Degree: IP20
  • Ambient Temperature: -5°C to +40°C

Ideal Applications:

  • Residential electrical distribution
  • Commercial building power systems
  • Industrial control panels
  • EV charging installations
  • High-rise building power distribution

  • 제품 세부 정보
  • Why Choose AHR3-63 RCBO
  • Packing & Delivery
  • FAQs

Introduction:

AHR3-63 Type A RCBOSmart Protection for EV Chargers & Modern Homes (6A-63A, 30mA-300mA)

Next-Gen Electrical Safety for DC-Sensitive Installations

As modern homes increasingly adopt EV chargers, solar systems, and smart appliances, the risk of DC fault currents grows. The AHR3-63 Type A RCBO delivers advanced protection by detecting both AC and pulsating DC leakage currentsmaking it the ideal choice for EV charging stations, PME systems, and PEN fault protection.

Key Benefits for Your Electrical System

Type A DetectionSafeguards against dangerous DC leakage from EV chargers & electronics
Dual ProtectionCombines 30mA-300mA earth leakage (RCD) + overload/short-circuit (MCB) protection
EV Charger ReadyComplies with IEC 60364-7-722 for electric vehicle installations
Wide Current Range6A to 63A versions for everything from lighting to high-power equipment
B & C Tripping CurvesB Curve (3-5x) for homes | C Curve (5-10x) for commercial use
Compact DesignSaves space vs separate RCD+MCB installations

Why Type A RCBOs Are Essential Today

Modern electrical systems face new risks:

  • EV chargers create pulsating DC currents that standard Type AC devices can’t detect
  • Solar inverters and variable-speed drives generate DC components
  • Smart home devices increase electronic load complexity

The AHR3-63 Type A RCBO solves these challenges by:

  • Detecting AC + pulsating DC faults (6mA+)
  • Providing instant disconnection (<0.1s at 30mA)
  • Offering true double-pole switching (L+N isolation)

Ideal Applications

🔌 EV Charging StationsMeets all regulatory requirements
🏠 Modern HomesProtects smart appliances & electronics
☀️ Solar InstallationsHandles DC components safely
🏢 Commercial BuildingsC Curve handles motor loads

Product Description

Key Features & Benefits

Electromagnetic TypeReliable operation without electronic components
Dual ProtectionRCD (30mA-300mA) + MCB (overload/short-circuit) in one unit
Type A DetectionEssential for EV chargers (detects pulsating DC currents)
10kA Breaking CapacityHandles high fault currents safely
B/C Tripping CurvesB Curve for homes, C Curve for commercial applications
True Double-Pole DisconnectionIsolates both Live & Neutral conductors
Easy InstallationTop/bottom wiring, 35mm DIN rail mounting
Neutral SwitchingReduces installation and testing time

AHR3-63 RCBO Technical Specifications

Category Parameter Specification
Standard Compliance IEC 61009-1, EN 61009-1
Electrical Rated Current (In) 6,10,16,20,25,32,40,50,63A
Type Electromagnetic
Leakage Detection Type Type A or AC
Poles 2 Pole (1P+N)
Rated Voltage (Ue) 230/240V
Sensitivity (IΔn) 30mA,100mA,300mA
Insulation Voltage (Ui) 500V
Frequency 50/60Hz
Breaking Capacity 10kA
Impulse Withstand Voltage 6kV (1.2/50μs)
Tripping Time ≤0.1s at IΔn
Pollution Degree 2
Tripping Characteristic B, C Curve
Mechanical Electrical Life 2,000 operations
Mechanical Life 10,000 operations
Contact Indicator Yes (Green=OFF, Red=ON)
Protection Degree IP20
Reference Temperature 30°C
Operating Temperature -5°C to +40°C
Storage Temperature -25°C to +70°C
Installation Terminal Type Cable/U-type/Pin-type busbar
Cable Size (Top/Bottom) 25mm² / 18-3 AWG
Busbar Size (Top/Bottom) 10mm² / 18-8 AWG
Tightening Torque 2.5N·m (22 In-lbs)
Mounting 35mm DIN Rail (EN 60715)
Connection Direction Top or Bottom

AHR3-63 Dimensions

EV Charger RCD Requirements: Complete Guide for Safe Installation

Do EV Chargers Need RCD Protection?

Yes! According to Regulation 722.531.3, all electric vehicle chargers must be protected by:

  • A 30mA RCD (Residual Current Device)
  • Full disconnection of both Live & Neutral conductors
    ⚠️ Single-pole RCBOs are NOT suitable for EV charger installations

Understanding RDC-DD in EV Chargers

What is RDC-DD?

RDC-DD (Residual Direct CurrentDisconnecting Device) is:

  • Built into many modern EV chargers
  • Monitors DC leakage currents on the AC side
  • Automatically disconnects if dangerous DC levels are detected

Choosing the Right RCD for Your EV Charger

Option 1: EV Charger WITHOUT RDC-DD

🔹 Required RCD: Type B
🔹 Why? Type B detects:

  • AC leakage (standard)
  • Smooth DC faults (which Type A cannot detect)

Option 2: EV Charger WITH RDC-DD (6mA detection)

🔹 Required RCD: Type A (most cost-effective)
🔹 Why?

  • Type A works safely with ≤6mA DC leakage (RDC-DD handles higher DC faults)
  • Most EV chargers now include RDC-DD, making Type A the standard choice

⚠️ Warning:

  • If DC leakage exceeds 6mA, a Type A RCD may fail to trip
  • Never use Type AC – it cannot detect DC faults at all!

RCD Installation Best Practices

Where to Install?

Consumer Unit (Preferred) – Ensures full circuit protection
Close to EV Charger (Alternative) – Required if no space in main panel

Critical Check!

🔎 Existing RCD Type?

  • Older installations may use Type AC RCDs
  • If the EV charger shares a circuit with Type AC:
    • DC leakage couldblindthe RCD
    • Other circuits lose protection
    • Risk of electric shock or fire

💡 Solution:

  • Upgrade to Type A/B for EV circuits
  • Separate circuit for EV charger recommended

Key Takeaways for EV Charger Safety

Scenario Correct RCD Type Notes
No RDC-DD Type B Mandatory for DC fault protection
With RDC-DD (6mA) Type A Most common & cost-effective
Old Installations Check Type! Replace Type AC with Type A/B

Why This Matters?

Prevents electric shocks (30mA protection)
🔥 Reduces fire risks (DC fault detection)
🚗 Ensures safe EV charging (compliance with IEC 60364)

Need help choosing the right RCD? Consult a certified electrician for safe EV charger installation!

Our RCBO offers the perfect balance of safety and performance, with:

  • Certified protection meeting international standards
  • Space-saving combined RCD+MCB functionality
  • Reliable operation in demanding environments
  • Flexible configuration options

Compliance & Certification:
Full compliance with IEC 61009-1 and EN61009-1 safety standards, ensuring reliable protection for your electrical installations.

This version:

  1. Organizes information into clear sections
  2. Highlights key benefits first
  3. Uses more professional language
  4. Maintains all technical details
  5. Improves readability
  6. Better suited for product catalogs and websites
  7. More appealing to professional buyers

Shipping choice

Q1: Wonder if you accept small orders?

A1: Do not worry. Feel free to contact us .in order to get more orders and give our clients more convenient ,we accept small order.

Q2: Can you send products to my country?

A2: Sure, we can. If you do not have your own ship forwarder, we can help you.

Q3: Can you do OEM for me?

A3: We accept all OEM orders,just contact us and give me your design.we will offer you a reasonable price and make samples for you ASAP.

Q4: What’s your payment terms ?

A4: By T/T,LC AT SIGHT,30% deposit in advance, balance 70% against the copy of B/L.

Q5: How can I place the order?

A5: First sign the PI,pay deposit,then we will arrange the production.After the goods finished production we will send u the copy of B/L then u paid. Finally u will get the goods.

Q7: When can I get the quotation ?

A7: We usually quote you within 24 hours after we get your inquiry. If you are very urgent to get the quotation.Please call us or tell us in your mail, so that we could regard your inquiry priority.